Effect of Delayed Scanning and Scanning Resolution Using Photostimulable Phosphor Plates on Detection of Vertical Root Fracture: In Vitro Study
Yükleniyor...
Tarih
2024
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
Objective: Detecting vertical root fractures (VRFs) can be challenging in dentistry due to their subtle and often concealed na- ture. This study aimed to assess the impact of varying resolutions and delayed scanning times of photostimulable phosphor plates on the di- agnosis of VRFs. Can different resolutions and/or delayed scan times enhance the diagnosis of VRFs?Material and Methods: In this in vitro study, forty extracted single-rooted premolar teeth were utilized. The crowns of all teeth were removed, and root canals were prepared. The teeth were divided into 2 groups: 20 study teeth with VRFs and 20 teeth without VRFs. VRFs were created using an Instron machine. All tooth roots were positioned in the premolar region of a dry human mandible and fixed with wax. Subsequently, periapical radiographs were taken using a parallel technique. Radiographs were scanned at 4 different times post-exposure: immediately, 30 minutes later, 2 hours later, and 4 hours later, and at three different resolutions: high speed, high reso- lution, and super high resolution. Statistical analyses were conducted using IBM SPSS statistics 26.0. Results: Intra- and interobserver agreement exhibited substantial to almost perfect ranges of agreement. Statistically significant differences were not observed in the diagnosis of VRFs when comparing different resolutions and scanning times. Conclusion: Varying resolutions and/or delayed scan times did not im- prove the diagnosis of VRFs. In clinical practice, a comprehensive de- tection of VRFs might necessitate a combination of different imaging techniques, immediately scanning, optimizing resolution settings, and clinical assessment.
Açıklama
Anahtar Kelimeler
Tanısal görüntüleme, Diagnostic imaging, Kök kanalı şekillendirmesi, Root canal preparation, İn vitro çalışma, İn vitro study
Kaynak
Türkiye Klinikleri Diş Hekimliği Bilimleri Dergisi
WoS Q Değeri
Scopus Q Değeri
Cilt
30
Sayı
1
Künye
ALAGÖZ, E., ÜNVER, T., TAK, A. Y., ÖZDEMİR, Ş. (2024). Effect of Delayed Scanning and Scanning Resolution Using Photostimulable Phosphor Plates on Detection of Vertical Root Fracture: In Vitro Study. Türkiye Klinikleri Diş Hekimliği Bilimleri Dergisi, 30(1),31-39. doi.org/10.5336/dentalsci.2023-99878